37
Lutron® integration protocol
Setup
Wired
RF
Communication
Repeater Status
1
3
4
2
M
Main Repeater
Power
Repeater Link
COM
9 V
1
N / C
MUX
MUX
2
3
4
AddTest
Integrate
Program / Integrate
RS232
Ethernet
USB
RadioRA® 2 (continued)
System Commands (continued)
TIMECLOCK Commands
TIMECLOCK Command Formats
TIMECLOCK Command-specific fields
Action Numbers and Parameters:
Action Action Number Parameters
Set (#) Current Timeclock
Mode
1
1 Mode
Get (?) Current Timeclock
Mode
1 None
Get (?) Sunrise Time 2 None
Get (?) Sunset Time 3 None
Get (?) Day’s Schedule 4 None
Execute (#) event 5 Index of the event to test. The index number of the first event
is 1; the second event is 2, and so on.
Enable/Disable Event 6 Event Index, Enable State (1 = Enable, 2 = Disable)
NOTE
1. In order to set the Timeclock Mode, the “mode” settings must first be determined using the ?help,#timeclock,1 command.
Example TIMECLOCK Messages
Operation Command String
Execute: #TIMECLOCK, Integration ID, Action Number, Parameters
Execute the 3rd event of the time clock. #TIMECLOCK,4,5,3<CR><LF>
Query: ?TIMECLOCK, Integration ID, Action Number
What is the sunrise time? ?TIMECLOCK,4,2<CR><LF>
Response: ~TIMECLOCK, Integration ID, Action Number, Parameters
The time the sun rises. ~TIMECLOCK,4,2,05:32<CR><LF>
Use “TIMECLOCK Command-specific fields” tables
to complete these command fields.
Operation
Command
#TIMECLOCK, 4, Action Number, Parameters
Integration ID (example)