NetLinx Programming
102
TPI-PRO/DVI (Total Presentation Interface)
"^" Button Commands (Cont.)
^APF
Add page flip
action to a button
if it does not
already exist.
Syntax:
"'^APF-<vt addr range>,<page flip action>,<page name>'"
Variables:
variable text address range = 1 - 4000.
page flip action =
Stan[dardPage] - Flip to standard page
Prev[iousPage] - Flip to previous page
Show[Popup] - Show Popup page
Hide[Popup] - Hide Popup page
Togg[lePopup] - Toggle popup state
ClearG[roup] - Clear popup page group from all pages
ClearP[age] - Clear all popup pages from a page with the specified page name
ClearA[ll] - Clear all popup pages from all pages
page name = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'^APF-400,Stan,Main Page'"
Assigns button address 400 to a standard page flip with page name 'Main Page'.
^BAT
Append
non-unicode text.
Syntax:
"'^BAT-<vt addr range>,<button states range>,<new text>'"
Variables:
variable text address range = 1 - 4000.
button states range =
1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and
2 = On state).
new text = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BAT-520,1,Enter City'"
Appends the text 'Enter City' to the button’s OFF state.
^BAU
Append unicode
text.
Same format as ^UNI.
Syntax:
"'^BAU-<vt addr range>,<button states range>,<unicode text>'"
Variables:
variable text address range = 1 - 4000.
button states range =
1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and
2 = On state).
unicode text = 1 - 50 ASCII characters. Unicode characters must be entered in Hex
format.
Example:
SEND_COMMAND Panel,"'^BAU-520,1,00770062'"
Appends Unicode text '00770062' to the button’s OFF state.