KI-1856C Rauland RANGER
®
Head End—
Installation
Page 23 of 55 (Jun-98)
RANEXPAD Master Port Expander
The
RANEXPAD
is a Master Port Expander that provides additional ports beyond those
available on a
RANEXP
(12+). You must have at least one
RANEXP
before you can add
an
RANEXPAD
. Each
RANEXPAD
adds an additional set of 12 runs of cable (with a
maximum of 60,000 pF). It requires 12
VDC
at 200 m
A
and is mounted in a single rack
space (1.75"). The
RANEXPAD
must be mounted in the same head-end as the
RANEXP
.
Parts Required
1
RANEXP
Master Port Expander
4 Mounting screws and washers (supplied with the
RANEXPAD
) or four mounting
screws (
RB
Part #
B
0439) and four washers (
RB
Part #
WL
0315)
12 Four-pin Phoenix connector (supplied with the
RANEXPAD
)
1 Pair shielded cable for connecting
AMX
Control Link
1 Connecting loop cable (one supplied per unit)
Associated Equipment
1 Six-terminal punch block (Graybar part #
S
66
B
3-75)
1 12
VDC
power source (e.g.,
RANPS12
)
1
RANCC16
Control Card Cage
Installation
1.
Mount the
RANEXPAD
(near the
RANEXP
).
2.
Connect the loop cable (supplied with
RANEXPAD
) from the Expansion “Out” port of
the
RANEXP
to the Expansion “In” port on the
RANEXPAD
. For every additional
RANEXPAD
unit, route a cable from the previous unit’s
RANEXPAD
“
Out” port to the
next unit's
RANEXPAD
“
In” port.
3.
Connect a 12
VDC
power supply to the
RANEXPAD
(e.g.,
RANPS
12).
4.
Connect the classroom runs from the
RANEXPAD
“
Axlinks”
ports to the punch blocks
(Graybar part # S66B3-75).
Connections and Settings of the Control
PC
The Control
PC
is required for all Ranger systems that have more than 120
classrooms or operator consoles. A classroom may comprise any combination of
RANCLASS
1s,
RANCLX
01
CPS
, Lesson Plan Workstations, or
R
a
NCL
100s (for older
systems). Although Version 4.51 contains the last new features that will be
developed for the
RANCPU
-based control system, Rauland-Borg will continue to
provide support and address any bugs that may be uncovered.