KI-1856C Rauland RANGER
®
Head End—
Installation
Page 16 of 55 (Jun-98)
Type of Cable
Maximum
Cumulative Distance
per RANEXP
Maximum
Cumulative
Distance per
RANBROAD
Maximum Distance
per AXLINK port
on the RANEXP or
RANBROAD
WP D291 25,300 23,000 2,300
WP 291 13,200 12,000 1,200
WP D2401 44,000 40,000 4,000
WP D252401
(Plenum)
44,000 40,000 4,000
Belden 8102 59,500 45,000 4,500
1.
Add up all the cable distances per classroom to calculate the total distance. See the
second column in the example that follows.
2.
Locate the cable that your are using in Table 5. Divide the Total cable distance
that you calculated in the previous step by the “Maximum Distance per
AXLINK
Port on the
RANEXP
or
RANBROAD
.”
3.
The number that you arrive at will determine the number of
RANEXP
or
RANBROAD AXLINK
ports needed (see the last column in the table below). If the
number you arrive at is larger than 12 for the
RANEXP
or 10 for the
RANBROAD
,
you will need to add an
RANEXPAD
or another
RANBROAD
.
Table 5.
RANEXP
or
RANBROAD
Port Estimation Example
Type of
Cable
Total Cable
Distance
Max. Distance per
AXLINK
Port on the
RANEXP or
RANBROAD
Number of RANEXP or
RANBROAD AXLINK
Ports
WP D291 4,870 2,300 3
WP 291 3,807 1,200 4
WP D2401 8,899 4,000 3
WP D252401
(Plenum)
7,065 4,000 2
Belden 8102 8,038 4,500 2
The number of punch blocks (
S
66
B
3-75) you need depends on the length of your
cable runs and the way you configure the
RANEXP
or
RANBROAD
ports.