AMX BCS Informações Técnicas

Consulte online ou descarregue Informações Técnicas para Software AMX BCS. AMX BCS Technical information Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 2

TECHNICAL INFORMATION SHUTTLE MOTOR SPECIFICATIONS SHUTTLE MOTOR:  Maximum torque: 1,5Nm  Maximum speed: 100rpm ≈ 15cm/sec  Current dra

Página 9

WAYS TO OPERATE THE FOREST SHUTTLE RF WIRELESS IR WIRELESS WIRED MULTI Z-WAVE SOMFY

Página 10 - 11/16”)

FOREST MULTI RECEIVER / WALL SWITCH – 5201001360 / 1 / 2 TECHNICAL SPECIFICATION: ● powered by Shuttle ● connect to port 1 of the Forest

Página 11

FOREST MULTI REMOTE - 5201001460 TECHNICAL SPECIFICATION: ● 3V battery CR2430 ● transmit range indoors max. 30mtr ● battery life > 3 ye

Página 13 - 15

FOREST MULTI REMOTE - 5201001460 MODE EXPLANATION: Mode manual (man): remote can only be used manually. Timer function is switched off. Mode au

Página 14

Z-WAVE REMOTE / RECEIVER INCLUDING THE SHUTTLE IN A Z-WAVE NETWORK*: select channel press include with pin, press b

Página 15

SCENE SETTING WITH Z-WAVE REMOTE Scene setting (intermediate positions) on a Shuttle track can only be use in combination with the Forest Z-wav

Página 16

Programming IR channels on Forest Shuttle To program a Forest Shuttle to a different channel you need a 12 channel IR remote control (52010022

Página 17 - 04/2011 WDOC CONTROL SHUTTLE

SHUTTLE PULSE WALL SWITCH - 5201001900 CONNECTING THE WALLSWITCH Either of the 2 ports (1-EYE or 2-AUX) can be used to connect a (pulse) sw

Página 18

Building automation wiring diagram for Forest Shuttle For control of a Forest Shuttle by a building automation system an actor is need

Página 19

Shuttle manual input features The default setting of the manual input of the Shuttle: - pulse connection between pin 3 and 1 → system OPENS, - p

Página 20

POTENTIAL FREE RELAY 5201002230 With this relay 230Vac control signals (for FMS or tubular motor) can be converted to two potential free contac

Página 21 - Z-WAVE REMOTE / RECEIVER

FIXING FMS ONTO FMS TRACK Please see page 3 – 6 for assemly of the track First position the motor sideways onto the motor pulley.

Página 22

TECHNICAL INFORMATION FMS MOTOR SPECIFICATIONS FMS MOTOR:  Torque: 0.8 / 1.2Nm / 1.8Nm (30 / 45 / 60Watt)  Speed: 100rpm ≈ 15cm/sec

Página 23 - simultaneously

CONTENT v1.8 1) Forest motorisation in general 1.0) Important instructions for Forest Shuttle 4 1.1) Step by step ass

Página 24

STEPS TO SET THE LIMITS OF THE FMS MOTOR Preferably set the limits of • Ensure that the two buttons on the bottom of the motor are

Página 26 - Shuttle motor

FOREST FMS/BCS MULTI RECEIVER - 5104011500 TECHNICAL SPECIFICATION: ● power 230Vac – 500W ● terminal max 2,5mm² ● controls one motor ●

Página 27

FMS/BCS Z-WAVE RECEIVER - 5201001812 FMS TUBULAR MOTOR (BCS) OR swit

Página 28 - FIXING FMS ONTO FMS TRACK

FMS/BCS Z-WAVE RECEIVER - 5201001812 Including a FMS/BCS receiver into a Z-wave controller network: Steps: 1) select channel on the controller

Página 29

SOMFY RECEIVER FOR FMS / BCS - 5104011410 10/2010 WDOC5201001900

Página 30 - OF THE FMS MOTOR

FMS / BCS PULSE WALL SWITCH - 5201001910 FMS TUBULAR MOTOR (BCS) OR

Página 31

Building automation wiring diagram for FMS / BCS For control of a FMS (Forest Motorized System) or BCS (Blind Contract System) by a bui

Página 32

MOTOR GROUP RELAY - 5201002240 For electrical decoupling of FMS or tubular motors in parallel connection. The FMS and tubular motors with mecha

Página 33

BLIND CONTRACT SYSTEM Keep in mind: ● the profile must be cut 1,5cm shorter than the total width of the system ● the octogonal tu

Página 34

IMPORTANT INSTRUCTIONS FOREST MOTORISATION Read these instructions carefully before using the Forest Shuttle, FMS and BCS motors and save them for f

Página 35

BLIND CONTRACT SYSTEM Installing the Blind Contract System Use one wall/ceiling bracket for every 50-60cm track length. Mount the

Página 36

07/2013 WDOC3416600XXX www.forestgroup.nl BCS TUBULAR MOTOR - BUILD-IN RECEIVER AND ELECTRONIC LIMIT SETTING

Página 37

07/2013 WDOC3416600XXX www.forestgroup.nl BCS TUBULAR MOTOR - BUILD-IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING

Página 38 - E E

07/2013 WDOC3416600XXX www.forestgroup.nl BCS TUBULAR MOTOR WITH BUILD-IN RECEIVER AND ELECTRONIC LIMIT SETTING A

Página 39

07/2013 WDOC3416600XXX www.forestgroup.nl BCS TUBULAR MOTOR WITH BUILD-IN RECEIVER AND ELECTRONIC LIMIT SETTING CAN

Página 40

OBSTRUCTION SENSOR SET - 3416800000 This product must be installed by a person with professional knowledge. The installer must comply with the

Página 41 - BUILD-IN RECEIVER

WAYS TO OPERATE BCS RF WIRELESS WIRED MULTI MULTI BUILD-IN Z-WAVE SOMFY MECH

Página 42 - BUILD-IN MULTI RECEIVER

WARRANTY & RETURN POLICY Forest Shuttle® Motors, BCS® and FMS® Devices. 1. The Forest Shuttle Motor and Control Devices are warrante

Página 43 - WITH BUILD-IN RECEIVER

STEP BY STEP ASSEMBLY OF THE FMS AND SHUTTLE TRACK Cut the track 10.5cm shorter than the total Cut the belt under an angle to remove

Página 44

STEP BY STEP ASSEMBLY OF THE FMS AND SHUTTLE TRACK Keep one side of the belt flush with the end of the rail. Now start counting 17 teeth

Página 45

STEP BY STEP ASSEMBLY OF THE FMS AND SHUTTLE TRACK Now position the center piece onto the Slide the master carrier to the end of t

Página 46 - WAYS TO OPERATE BCS

STEP BY STEP ASSEMBLY OF THE FMS AND SHUTTLE TRACK Now reposition the end pulley onto the track Place the metal FMS clip inside the

Comentários a estes Manuais

Sem comentários