MOTOR GROUP RELAY - 5201002240
For electrical decoupling of FMS or tubular motors in parallel connection.
The FMS and tubular motors with mechanical limit-switches must as a rule not be electrically connected
directly in parallel, because due to the different motor running times the limit-switches of some motors may
be reached while other motors are still running. The motors that are already switched off would then receive
inductive voltage at the counter-winding from the motors that are still running, which can lead to destruction
of the limit-switches. The Motor Group relay is providing an extremely simple method of achieving a
(functional) parallel circuit. Several relais can be connected parallel.
Technical specification:
Operating voltage: 230Vac 50Hz
Power consumption: 0.6W
Relay contacts: 4 NO contacts, 10A/250Vac
Ambient temperature -10°C to +45°C
Terminal: max. 2.5mm²
Dimensions: 43x43x18.5mm
Weight approx.: 40g
Wiring diagram:
Line
open close
.
Neutral
Earth
06/2011 WDOCMOTRELAY www.forestgroup.nl