SIMATIC S7-1200
Central processing units
CPU 1214C
4/25
Siemens ST 70 · 2011
Technical specifications (continued)
4
Digital inputs
Number of digital inputs 14; Integrated 14; Integrated 14; Integrated
• of which, inputs usable for techno-
logical functions
6; HSC (High Speed Counting) 6; HSC (High Speed Counting) 6; HSC (High Speed Counting)
m/p-reading Yes Yes Yes
Input voltage
• Rated value, DC 24 V 24 V 24 V
• for signal "0"
5 V DC at 1 mA
• for signal "1" 15 V DC at 2.5 mA
Input current
• for signal "1", typ. 1mA 1mA 1mA
Input delay (for rated value of input
voltage)
• for standard inputs
- parameterizable 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and
12.8 ms, selectable in groups of
four
0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and
12.8 ms, selectable in groups of
four
0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and
12.8 ms, selectable in groups of
four
- at "0" to "1", min. 0.2 ms 0.2 ms 0.2 ms
- at "0" to "1", max. 12.8 ms 12.8 ms 12.8 ms
• for interrupt inputs
- parameterizable Yes Yes Yes
• for counter/technological functions
- parameterizable Single phase : 3 at 100 kHz & 1 at
30 kHz, differential: 3 at 80 kHz &
1 at 30 kHz
Single phase : 3 at 100 kHz & 1 at
30 kHz, differential: 3 at 80 kHz &
1 at 30 kHz
Single phase : 3 at 100 kHz & 3 at
30 kHz, differential: 3 at 80 kHz &
3 at 30 kHz
Cable length
• Cable length, shielded, max. 500 m; 50 m for technological
functions
500 m; 50 m for technological
functions
500 m; 50 m for technological
functions
• Cable length unshielded, max. 300 m; For technological functions:
No
300 m; For technological functions:
No
300 m; For technological functions:
No
Digital outputs
Number of digital outputs 10 10 10
• of which high-speed outputs 2; 100 kHz Pulse Train Output
Short-circuit protection No; to be provided externally No; to be provided externally No; to be provided externally
Limitation of inductive shutdown
voltage to
L+ (-48 V)
Switching capacity of the outputs
• with resistive load, max. 2A 0.5 A 2A
• on lamp load, max.
30 W DC; 200 W AC 5W 30 W DC; 200 W AC
Output voltage
• for signal "1", min. 20 V
Output current
• for signal "1" rated value 0.5 A
• for signal "0" residual current, max. 0.1 mA
Output delay with resistive load
• 0 to "1", max. 10 ms; max. s 10 ms; max.
• 1 to "0", max.
10 ms; max. s 10 ms; max.
Switching frequency
• of the pulse outputs, with resistive
load, max.
1Hz 100 kHz 1Hz
Cable length
• Cable length, shielded, max. 500 m 500 m 500 m
• Cable length unshielded, max. 150 m 150 m 150 m
6ES7 214-1BE30-0XB0 6ES7 214-1AE30-0XB0 6ES7 214-1HE30-0XB0
© Siemens AG 2011
© Siemens AG 2011