13
38. It is no longer possible to set the network address in CSD to an inaccessible range. (#6589)
39. When power to the PM8500/N was lost the ‘AC power loss’ entry to the alarm log could sometimes be
missed, this has now been corrected (#6540)
40. It was possible for the polarity indication within the PM8500/N output panel to become out-of sync
when changing from V-bridge/Ishare to Quad-bridge with the polarity reversed. This is resolved.
v3.044 (November, 2011)
Changes/Bug fixes
1. Recovery mode supported for PowerMatch supported via USB4865)
v3.043 (October, 2011)
New Features
1. PowerMatch PM8500/N Configurable Multi-Channel Professional Amplifiers
This version of ControlSpace Designer includes many additions and enhancements to support the new
PowerMatch PM8500 and PM8500N Professional Power Amplifiers.
Output Configuration
Each channel pair can be configured for individual, voltage bridged or current sharing operation to match
different loads. In addition two channel pairs can be combined in QuadBridge™ mode to deliver 4x the
power of a single channel. The output configuration is defined in the PM8500/N properties.
Connection via USB
Direct connection to a single PM8500/N using a standard USB connection.
DHCP (PM8500N only)
By default, the PM8500N uses DHCP to obtain an IP address automatically on power-up. DHCP can be
disabled from CSD.
Standby Control (PM8500N only)
Allows the PM8500N amplifier to be put into standby or turned on remotely via Parameter Set recall.
Limiter Link Groups
When linked, gain reduction is applied equally to all members of the Link Group when limiting on any of
linked channels occurs.
• Load measurement
The load impedance of each PM8500/N output may be measured and recorded using ControlSpace
Designer for diagnostic or documentation purposes. Reference sweeps are stored within the
ControlSpace Designer project file for future comparison.
• Monitoring and Alarms
The PM8500/N maintains an internal log of alarm and fault conditions that maybe retrieved, viewed and
cleared via ControlSpace Designer.