AxLink Device Addressing
1. If connected, disconnect the power supply.
2. Locate the 8-position mini-DIP switch on the rear panel.
3. Set the DIP switch according to the values shown below.
The device number is set by the total value of DIP switch positions that are in the ON position. Note that
the ON position is indicated on the DIP Switch.
As an example, the DIP switch in FIG. 14 defines AXlink device number 129 (1+128=129).
If you later change the device number, remove and reconnect the power connector to enter the new device
number into memory.
Switch12345678
Value 1 2 4 8 16 32 64 128
FIG. 2
8-position mini-DIP Switch
AMX has created the "Dip Switch2" software application to assist in calculating dip
switch position values. Download the (free) program Dip Switch2 from
www.amx.com.