AMX AXC-232 Plus plus Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
12 Rockwell Automation Publication 2711P-TD005E-EN-P - March 2015
PanelView Plus 6 Specifications
External Power Supply
This safety extra-low voltage (SELV) or protective extra-low voltage (PELV), 24V DC power supply can be used to power
any of the PanelView Plus 6 terminals with a DC power input. This power supply provides protection so that under normal
and single fault conditions, the voltage between conductors and earth ground does not exceed a safe value.
Table 10 - Environmental Specifications - 2711P-RSACDIN Power Supply
Attribute 2711P-RSACDIN
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold)
IEC 60068-2-2 (Test Bd, Operating Dry Heat)
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
0…55 °C (32…131 °F)
Temperature, storage
IEC 60068-2-1 (Test Ab, Unpackaged, Nonoperating Cold)
IEC 60068-2-2 (Test Bb, Unpackaged, Nonoperating Dry Heat)
IEC 60068-2-14 (Test Nb, Unpackaged, Nonoperating Thermal Shock)
-40…85 °C (-40…185 °F)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged, Nonoperating Damp Heat)
5...95% noncondensing
Vibration
IEC 60068-2-6 (Test Fc, Operating)
5 g at 10…500 Hz
Shock, operating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Shock, nonoperating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
ESD immunity
IEC 61000-4-2
4 kV contact discharges
8 kV air discharges
Radiated RF immunity
IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 30…1000 MHz
EFT/B immunity
IEC 61000-4-4
±2 kV at 5 kHz on power ports
Surge transient immunity
IEC 61000-4-5
±1 kV line-line (DM) and ±2 kV line-earth (CM) on AC power ports
Conducted RF immunity
IEC 61000-4-6
10V rms with 1 kHz sine wave 80% AM from 150 kHz…80 MHz
Enclosure type rating None (open-style)
Power conductors
Wire size
Category
12 gauge (4 mm
2
) max solid or stranded copper wire rated at 75 °C (167 °F) or greater
1.2 mm (3/64 in.) insulation max
1
(1)
(1) Use this conductor capacity information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 11 - Certifications - 2711P-RSACDIN Power Supply
Certification
(1)
(1) When marked. See the Product Certifications page at http://www.rockwellautomation.com/rockwellautomation/certification/overview.page for
Declarations of Conformity, Certificates, and other certification details.
2711P-RSACDIN
c-UL-us
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E10314.
UL Listed for Class, Division 2 Groups A, B, C, and D for US and Canada.
CE
European Union 89/336/EEC EMC Directive, compliant with:
EN 61000-6-2; Industrial Immunity
EN 61326, Meas./Control/Lab., Industrial Requirements
EN 61000-6-4; Industrial Emissions
European Union 73235/EEC Low Voltage Directive, compliant with:
EN 61131-2; Programmable Controllers
C-Tick
Australian Radiocommunications Act, compliant with:
AS/NZS 2064, Industrial Emissions
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Comentários a estes Manuais

Sem comentários