Terminal (Program Port/Telnet) Commands
102
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3)
Terminal Commands (Cont.)
Command Description
SET DATE Prompts you to enter the new date for the Master.
When the date is set on the Master, the new date will be reflected on all
devices in the system that have clocks (i.e. touch panels).
By the same token, if you set the date on any system device, the new
date will be reflected on the system’s Master, and on all connected
devices.
Note: This command will not update clocks on devices connected to
another Master (in Master-to-Master systems).
Example:
>SET DATE
Enter Date: (mm/dd//yyyy) ->
SET DNS <D:P:S> Sets up the DNS configuration of a device.
This command prompts you to enter a Domain Name, DNS IP #1, DNS IP
#2, and DNS IP #3.
Then, enter Y (yes) to approve/store the information in the Master.
Entering N (no) cancels the operation.
Note: The device must be rebooted to enable new settings.
Example:
>SET DNS [0:1:0]
-- Enter New Values or just hit Enter to keep current
settings --
Enter Domain Suffix: amx.com
Enter DNS Entry 1 : 192.168.20.5
Enter DNS Entry 2 : 12.18.110.8
Enter DNS Entry 3 : 12.18.110.7
You have entered: Domain Name: amx.com
DNS Entry 1: 192.168.20.5
DNS Entry 2: 12.18.110.8
DNS Entry 3: 12.18.110.7
Is this correct? Type Y or N and Enter -> Y
Settings written. Device must be rebooted to
enable new settings
SET DUET MEMORY Set the amount of memory allocated for Duet Java pool. This is the cur-
rent Java memory heap size as measured in Megabytes. This
feature is used so that if a NetLinx program requires a certain size of
memory be allotted for its currently used Duet Modules, it can be reserved
on the target Master.
Valid values are:
2 - 8 for 32MB systems
2 - 36 for 64MB systems.
This setting does not take effect until the next reboot.
Note: If you are trying to accomplish this setting of the Duet Memory size
via a NetLinx program, the program command
"DUET_MEM_SIZE_SET(int)" should call REBOOT() following a set.