AMX NI-3100 Especificações Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 160
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
Initial Configuration and Firmware Upgrade
11
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3)
a. Select NetLinx Master (under Platform Selection) to indicate you are working with a NetLinx
Master.
b. Select TCP/IP (under Transport Connection Option) to indicate you are connecting to the Master via
an IP Address.
4. Click New to open the New TCP/IP Setting dialog, where you can enter both a previously obtained DHCP
or Static IP Address and an associated Description for the connection into their respective fields.
(FIG. 11):
Verify that the Automatically Ping the Master Controller to ensure availability option is selected to
make sure the Master is initially responding online before establishing full communication.
If the authentication is required for connecting to the Master at this address, enter a User Name and
Password in the text fields provided.
5. Click OK to close the New TCP/IP Settings dialog and return to the Communication Settings dialog:
(FIG. 12).
FIG. 10 NetLinx Studio - Communication Settings dialog
FIG. 11 NetLinx Studio - New TCP/IP Setting dialog
Vista de página 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 159 160

Comentários a estes Manuais

Sem comentários