Programming
104
Modero G4 Touch Panels - Configuration and Programming
SIP Call Management Commands
The following table lists and describes SIP commands that are sent to the touch panel to manage calls. SIP commands
only apply to Modero X/S Series G4 panels equipped with SIP functionality (excluding all "No Comm" panels). .
SIP Call Management Commands
^PHN-ANSWER Answers the call.
Syntax:
"'^PHN-ANSWER, <connection id>'"
Variable:
connection id = The identifying number of the connection
Example:
SEND_COMMAND Panel,"'^PHN-ANSWER, 1'"
^PHN-AUTOANSWER Enables (1) or disables (0) the auto-answer feature on the phone.
Syntax:
"’^PHN-AUTOANSWER, <state>’"
Variable:
state = 0 (Disable) or 1 (Enable)
Example:
SEND_COMMAND Panel,"'^PHN-AUTOANSWER, 1'"
Enables the auto-answer feature.
?PHN-AUTOANSWER Queries the state of the auto- answer feature. The panel responds with the ^PHN-
AUTOANSWER, <state> message.
Syntax:
"’?PHN-AUTOANSWER’"
Example:
SEND_COMMAND Panel,"'?PHN-AUTOANSWER'"
^PHN-CALL Calls the provided number.
Syntax:
"’^PHN-CALL, <number>’"
Variable:
number = The provided phone number
Example:
SEND_COMMAND Panel,"'^PHN-CALL, 2125551000'"
^PHN-DTMF Sends DTMF codes.
Syntax:
"’^PHN-DTMF, <DTMF code>’"
Variable:
DTMF code = 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, POUND, or ASTERISK.
Example:
SEND_COMMAND Panel,"'^PHN-DTMF, 1234567879ASTERISK'"
^PHN-HANGUP Hangs up the call.
Syntax:
"’^PHN-HANGUP, <connection id>’"
Variable:
connection id = The identifying number of the connection
Example:
SEND_COMMAND Panel,"'^PHN-HANGUP, 1'"
^PHN-HOLD Places the call on hold.
Syntax:
"’^PHN-HOLD, <connection id>’"
Variable:
connection id = The identifying number of the connection
Example:
SEND_COMMAND Panel,"'^PHN-HOLD, 1'"